Changes to Step #18
Step Lines
+ | [title] Wire the second 48V Power supply |
---|---|
+ | [* 10] It is recommended to wire the power supply before installing it in the electronics enclosure. Please connect the following wires: |
+ | [* 2] 2x 800mm - 16AWG RED (A-Fork, B-Ferrule) (15) |
+ | [* 3] 2x 800mm - 16AWG BLACK (A-Fork, B-Ferrule) (16) |
+ | [* 4] 130mm - 18AWG BROWN (A-Fork, B-Fork) (38) |
+ | [* 5] 130mm - 18AWG BLUE (A-Fork, B-Fork) (39) |
+ | [* 6] 130mm - 18AWG YELLOWGREEN (A-Fork, B-Fork) (40) |
+ | [* 10] Wires 38, 39, and 40 must be installed in the same screw terminals as wires 41, 36, and 35, as indicated in the diagram for the first 48V power supply, which was prepared in the previous step. |