+[title] Wire the contactor - Part 3
+[* 2] 700mm - 16AWG BLACK (A-Fork, B-Ferrule) (9)
+ [* 10] Insert wire (9) in the A2 terminal on the contactor and connect it to the -24V Black PTFix with the ferrule.
+ [* 10] Route the wire as shown.
+ [* 9] After insertion, attempt to pull the wire to verify that it is securely attached.