Skip to main content

You're viewing a previously published revision of this guide.  View latest revision

Older Newer
  1. Phaetus Rapido V2 UHF Hotend
    • Phaetus Rapido V2 UHF Hotend

    • Cut the wires with 150mm and strip 5-10mm of the end, to expose the inside conductor.

    • Cut the thermistor wires with 160mm and crimp a JST 2 connector

    • The thermistor is a resistor that strongly varies with temperature. When crimping a resistor you don't have to worry about wire order as resistors don't have polarity.

  2. Hot End Heater 24V Insert the cable ends on the designated slots and tighten the screws. After tightening the screws, pull the cable to make sure it's firmly connected. If the cable releases/moves when pulling, reinsert it and tighten the screw.
    • Hot End Heater 24V

    • Insert the cable ends on the designated slots and tighten the screws.

    • After tightening the screws, pull the cable to make sure it's firmly connected. If the cable releases/moves when pulling, reinsert it and tighten the screw.

    • Hot End Thermistor

    • Plug the connector into the designated connector.

    • The thermistor wires are very fragile, bending them past its threshold can damage the conductors within, leading to wire failure.

    • Insert the highlighted jumper to achieve more accurate temperature readings

    • Route the wires accordingly.

  3. Connect the orbiter extruder cable to the designated slot on the toolboard Route the wires accordingly.
    • Connect the orbiter extruder cable to the designated slot on the toolboard

    • Route the wires accordingly.

  4. Hot End 4010 fan - 24V Connect the positive and negative wires to the referred slot.
    • Hot End 4010 fan - 24V

    • Connect the positive and negative wires to the referred slot.

    • Route the cable accordingly.

    • Use a zip tie to ensure the cable is secure to the toolhead body.

  5. Cable 120mm - 3 Conductor 24AWG - JST XH2.54 male to Bare wire Micro JST 5pins provided with the EBB42 Toolboard package
    • Cable 120mm - 3 Conductor 24AWG - JST XH2.54 male to Bare wire

    • Micro JST 5pins provided with the EBB42 Toolboard package

    • Crimp the connector on the 3 wires as shown.

    • Refer to this picture to clearly show where the wires go

  6. Warning: Check your cables. Incorrect endstop wiring can damage your board. Rat Rig Omron X endstop
    • Warning: Check your cables. Incorrect endstop wiring can damage your board.

    • Rat Rig Omron X endstop

    • Endstop 3 wire cable - Prepared previously.

    • Connect the JST3 connector to the shown slot on the toolboard.

    • Route the cable accordingly.

  7. 4x Crimp - Molex Micro-Fit (43025 compatible)
    • 4x Crimp - Molex Micro-Fit (43025 compatible)

    • Connector - Molex Micro-Fit - 4 Pin - Male (43025-0400)

    • 3x Crimp - Molex Micro-Fit (43020 compatible)

    • Connector - Molex Micro-Fit - 4 Pin - Female (43020-0400)

    • 2x Connector - 2 Pin - JST XHP-2 - 2.54 Male

    • 4x Crimp - JST XH 2.54

    • Cable 1500mm - 3 Conductor 24AWG - JST XH2.54 to JST XH2.54

Rat Rig

Member since: 7/10/20

48,550 Reputation

105 Guides authored

View Statistics:

Past 24 Hours: 9

Past 7 Days: 72

Past 30 Days: 386

All Time: 8,985