  1. 120mm - 16AWG RED (A-Fork, B-Fork) (4) Insert wire (4) in the 13NO terminal on the contactor and connect it to the A1 terminal of the contactor. After insertion, attempt to pull the wire to verify that it is securely attached.
    • 120mm - 16AWG RED (A-Fork, B-Fork) (4)

    • Insert wire (4) in the 13NO terminal on the contactor and connect it to the A1 terminal of the contactor.

    • After insertion, attempt to pull the wire to verify that it is securely attached.

    • 800mm - 16AWG RED (A-Fork, B-Ferrule) (5)

    • Insert wire (5) in the 5/L3 terminal on the contactor and connect it to the +24V Red PTFix block.

  2. 800mm - 16AWG RED (A-Fork, B-Fork) (6) Route the wire as shown. Insert wire (6) in the 6/T3 terminal on the contactor and connect it to the +24V Rodent input.
    • 800mm - 16AWG RED (A-Fork, B-Fork) (6)

    • Route the wire as shown.

    • Insert wire (6) in the 6/T3 terminal on the contactor and connect it to the +24V Rodent input.

    • After insertion, attempt to pull the wire to verify that it is securely attached.

  3. 700mm - 16AWG BLACK (A-Fork, B-Ferrule) (9) Insert wire (9) in the A2 terminal on the contactor and connect it to the -24V Black PTFix with the ferrule.
    • 700mm - 16AWG BLACK (A-Fork, B-Ferrule) (9)

    • Insert wire (9) in the A2 terminal on the contactor and connect it to the -24V Black PTFix with the ferrule.

    • Route the wire as shown.

    • After insertion, attempt to pull the wire to verify that it is securely attached.

  4. 100mm - 16AWG BLACK (A-Fork, B-Ferrule) (10) Insert wire (10) on the -24V Black PTFix with the ferrule and connect it to the -24V Rodent input. Route the wire as shown.
    • 100mm - 16AWG BLACK (A-Fork, B-Ferrule) (10)

    • Insert wire (10) on the -24V Black PTFix with the ferrule and connect it to the -24V Rodent input.

    • Route the wire as shown.

    • After insertion, attempt to pull the wire to verify that it is securely attached.

  5. 740mm - 16AWG RED (A-Fork, B-Ferrule) (7)
    • 740mm - 16AWG RED (A-Fork, B-Ferrule) (7)

    • This wire should be attached to the power supply 02. Common components . Route it as shown and connect the ferrule end to the +24V RED PTFix terminal.

    • 740mm - 16AWG BLACK (A-Fork, B-Ferrule) (8)

    • This wire should be attached to the power supply 02. Common components . Route it as shown and connect the ferrule end to the -24V BLACK PTFix terminal.

    • After insertion, attempt to pull the wire to verify that it is securely attached.