120mm - 16AWG RED (A-Fork, B-Fork) (4)
-
Insert wire (4) in the 13NO terminal on the contactor and connect it to the A1 terminal of the contactor.
-
After insertion, attempt to pull the wire to verify that it is securely attached.
-
800mm - 16AWG RED (A-Fork, B-Ferrule) (5)
-
Insert wire (5) in the 5/L3 terminal on the contactor and connect it to the +24V Red PTFix block.
-
-
-
800mm - 16AWG RED (A-Fork, B-Fork) (6)
-
Route the wire as shown.
-
Insert wire (6) in the 6/T3 terminal on the contactor and connect it to the +24V Rodent input.
-
After insertion, attempt to pull the wire to verify that it is securely attached.
-
-
-
700mm - 16AWG BLACK (A-Fork, B-Ferrule) (9)
-
Insert wire (9) in the A2 terminal on the contactor and connect it to the -24V Black PTFix with the ferrule.
-
Route the wire as shown.
-
After insertion, attempt to pull the wire to verify that it is securely attached.
-
-
-
100mm - 16AWG BLACK (A-Fork, B-Ferrule) (10)
-
Insert wire (10) on the -24V Black PTFix with the ferrule and connect it to the -24V Rodent input.
-
Route the wire as shown.
-
After insertion, attempt to pull the wire to verify that it is securely attached.
-
-
-
740mm - 16AWG RED (A-Fork, B-Ferrule) (7)
-
This wire should be attached to the power supply 02. Common components . Route it as shown and connect the ferrule end to the +24V RED PTFix terminal.
-
740mm - 16AWG BLACK (A-Fork, B-Ferrule) (8)
-
This wire should be attached to the power supply 02. Common components . Route it as shown and connect the ferrule end to the -24V BLACK PTFix terminal.
-
After insertion, attempt to pull the wire to verify that it is securely attached.
-
-
-
You will need to cut the JST connector on the Fans - 120mm x 15mm, as well as crimp a ferrule to each wire.
-
Insert both Red wires from the fans into the +24V RED PTFix terminal.
-
Insert both Black wires from the fans into the -24V Black PTFix terminal.
-