T-Plate Assembly

Follow these steps for each of the 6 T-plate assembly positions shown:

Align the T-plate assembly so that it is flush with the 3030 extrusion

Measure the gap between the T-plate assembly and the corner plate assembly

For a 200 build, the measurement should be 80mm

For 300, 400 & 500 builds, the measurement should be 130mm

Secure the T-shaped plate to the extrusion by fastening the three M6x12 screws

Double check all measurements before proceeding to the next step